Reverse Osmosis Specialty Antiscalant

Select-3063

Product Overview

Select-3063 (12x Concentrate) is a highly concentrated antiscalant produced by VCS USA, featuring strong scale inhibition and high dispersion performance. It prevents the precipitation of scale-forming metal inorganic salts, soluble silica, and other scaling inorganics in RO concentrate. It is widely used in industries such as petroleum, power generation, food, pharmaceuticals, chemical,and steel.

Advantages:

  • Controls inorganic scale over a wide concentration range and can be applied to various water qualities while maintaining high scale inhibition efficiency, reducing the frequency of membrane cleanings
  • Does not coagulate with iron/aluminum oxides or silica compounds to form insoluble matter
  • Exhibits excellent solubility and stability
  • Effectively inhibits silica polymerization and deposition; concentrate side SiOâ‚‚ concentration can reach up to 290 ppm
  • Can be used for RO CA and TFC membranes, nanofiltration membranes, and ultrafiltration membranes
  • Particularly suitable for high-salinity water
  • Particularly suitable for highly polluted reclaimed water Particularly suitable for surface water withhigh biological activity
  • Particularly suitable for coolingtowerblowdown water with high phosphorus content
  • Effective across a feed water pHrangeof5–10; very low dosage provides cost-effectivescale control

Physical and Chemical Properties:

  • Appearance: Colorless or clear pale amber green
  • Density: 1.2 ± 0.05 g/mL
  • Freezing point: 0°C
  • Boiling point: 100.5°C
  • Percent viscosity: 50%
  • pH value: 1.5–2.5
  • Solubility: Completely soluble in water

Directions for Use:

For typical water quality, continuously dose 0.25–0.42 ppm (as 12x concentrate) upstream of the cartridge filter. The specific dosage can be calculated using specialized software.
When a significant amount of organic matter is present in the water, this product has a certain capacity to adsorb and control it. On top of the 0.27–0.42 ppm (as 12x concentrate) dosage used for inorganic scale inhibition, additional antiscalant may be dosed proportionally based on a VCS technician’s recommendation to effectively extend the RO cleaning cycle.
Note: When applying this product, prepare the dilution using RO permeate water. Pay attention to interference from excessive organic high-molecular-weight cationic flocculants in the pretreatment (membrane elements are generally negatively charged, so excessive use of organic high-molecular-weight cationic chemicals should be avoided; the use of metal salt coagulants such as PAC is recommended, while ensuring overdosing is prevented).

Handling Precautions:

Wear protective clothing, rubber gloves, eye protection, and a face shield. Avoid contact with skin, eyes, and mucous membranes. Wash after handling, and shower upon completion of work.

Storage Precautions:

Store in a cool, well-ventilated warehouse.Keep away from fire sources and heat. Storage temperature should not exceed 40°C or fall below 0°C. Keep containers tightly sealed.Should be stored separately from oxidizers and edible chemicals; mixed storage is strictly prohibited. Protect from light.